Battery Racks

Ac Charger
Ac Charger

Key Advantages

Our advanced Battery Racks offer high-performance, modular, and scalable solutions designed for critical backup and peak load support. Built for demanding industrial applications, these battery racks deliver robust power with a compact footprint and superior safety features.

Battery Module LION Battery Solutions
Rated Voltage       64V 512V
Rated Energy (KWH) 6.4 51.2
MIN Energy (KWH) 6.08 48.6
Voltage Range(V) 54V~72V 432V~584V
Rated Discharge Current                                               400A(4) -
MAX Discharge Current 600A(6C) -
Rated Charge Current 50A -
MAX Charge Current 100A -
COM - CAN/RS485/Dry Contact
Compatiblity - Compatible with main UPS
Protection Function - Over-charge/Discharge, over-temp, over-current, short-circuit and etc
Size (W*D*H) (mm) 526 x 617 x 150 600 x 860 x 2000 (including foot)
Wieght (kgs) 62 kgs 816 kgs
Enclosure IP20 IP54

DC Chargers


DC Chargers
DC Chargers

Key Advantages

30-60 kW 120 kW
INPUT VOLTAGE Nominal Voltage 380/400/415 (L-L)
Voltage range 320-520 VAC
Nominal Voltage 380/400/415 (L-L)
Voltage range 320-520 VAC
POWER CURRENT 46A/phase or 78A L-L 33kVA for 30kW 400AC (L-L)
93A/phase or 125 A L-L 65kVA for 60 kW
22kW outlet type 2 (optional)
92 A/ Phase or 186A L-L, 129kVA for 120 kW @ 400 AC (L-L)
22kW outlet type 2 (optional)
PHASE Three phase TN-S connected 4 Wire Three phase TN-S connected 4 Wire
CAR CHARGING TIME 30KW: Less than 80 min
60KW: Less than 60 min
120KW: Less than 60 min
POWER LOSS (standby) < 60 Watts < 60 Watts
COMMUNICATION WiFi / GSM / Ethernet-RJ45 WiFi / GSM / Ethernet-RJ45
PROTOCOL OCPP 1.6 J OCPP 1.6 J
ENCLOSURE IP 54 IP 54
OPERATING TEMP. -30 to 75 *C -30 to 75 *C
APPLICABLE STANDARD Complied as per Safety: IEC 61851-1; IEC 61851-21-2; IEC 61851-23; IEC 61851-24; IEC 62196-1; IEC 62196-3; IEC 61000 Other: ARAI (AIS 138 Part 2) Vehicle Communication: DIN 70121, ISO 15118 Complied as per Safety: IEC 61851-1; IEC 61851-21-2; IEC 61851-23; IEC 61851-24; IEC 62196-1; IEC 62196-3; IEC 61000 Other: ARAI (AIS 138 Part 2) Vehicle Communication: DIN 70121, ISO 15118

Rope Chargers


Rope Chargers
Rope Chargers
Rope Chargers

Key Advantages

3.3 KW & 7.4 KW
INPUT VOLTAGE 230 +/- 10 Volt
POWER CURRENT 3.3 kW 16 Amps or 7.4 KW 32 Amp
PROTECTION OL, UV, OC, UC,EF
PHASE Single/ three
CAR CHARGING TIME (30-40 kwh) 3.3 KW: Less than 12 hrs
7.4 KW: Less than 6 hrs
POWER LOSS (standby) < 20 Watts
COMMUNICATION With Vehicle: PWM based
CABLE LENGTH , WEIGHT 5 meters , 2.5 KG
ENCLOSURE IP 65 outdoor standalone; Plastic ABS
OPERATING TEMP. -20 to 50 *C
APPLICABLE STANDARD IS17017 (Part 2/Sec 7): 2023;
IEC 61851-1;
IEC 62196-2-II
CONNECTOR TYPE Type 2 gun as power IEC-2196-2 II

Inverter Duty Transformer


inverter duty transformer
inverter duty transformer



We specifically design inverter-duty transformers for Wind and Solar Energy applications and provide them with multiple windings on the primary/secondary side of the transformer. We also provide Earth Shield between the HV and LV windings whose purpose is to reduce harmonic and path-to-ground residual resonance.

Our range of IDT varies from up to 18.5 MVA, the precise requirements vary from device to device and from site to site. We offer Inverter Duty Transformers in ONAN and ONAF cooling.